Installation

7 SERIES

Professional Freestanding Ranges

VGR736, CVGR736, VGR748, CVGR748 VDR736, CVDR736, VDR748, CVDR748

Table of Contents

 

•    Before beginning, please read these instructions completely and carefully.

   DO NOT remove permanently affixed labels, warnings, or plates from product.

This may void the warranty.

•    All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSI Z223.1 INFPA54.

•    The installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.

In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.

In Massachusetts: All gas products must be installed by a “Massachusetts” licensed plumber or gasfitter. A “T” type handle manual valve must be installed in the gas supply line to the appliance.

An air curtain or other overhead range hood which operates by blowing a downward airflow onto the range, shall not be used with a gas range

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.

All safety messages will be preceded by the safety alert symbol and the word “DANGER,” “WARNING” or “CAUTION.” These words mean:

A DANGER

Hazards or unsafe practices which WILL result in severe personal injury or death.

A WARNING

Hazards or unsafe practices which COULD result in severe personal injury or death.

A CAUTION

Hazards or unsafe practices which COULD result in minor personal injury or property damage.

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local

laws, or local ordinances.

•    The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.

•    Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.

If the use of a GFI is required, it should be:

•    Of the receptacle type (breaker type or portable type NOT recommended)

•    Used with permanent wiring only (temporary or portable wiring NOT recommended)

•On a dedicated circuit (no other receptacles, switches or loads in the circuit)

•    Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)

•    Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard

•    In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)

•    Protected from moisture (water, steam, high humidity) as much as reasonably possible

A WARNING

 

A DANGER

 

To prevent possible damage to cabinets and cabinet finishes, use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194°F (90°C). Heat resistant adhesive must be used if the product is to be installed in laminated cabinetry. Check with your builder or cabinet supplier to make sure that the materials meet these requirements.

 

 

FIRE/EXPLOSION HAZARD

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.

   DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

   WHAT TO DO IF YOU SMELL GAS: DO NOT try to light any appliance.

DO NOT touch any electrical switch;

DO NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone.

-Follow the gas supplier’s instructions. -If you cannot reach your gas supplier, call the fire department.

•    Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

A DANGER

 

A WARNING

 

CHEMICAL HAZARD

To avoid risk of property damage and/or personal injury or death; this appliance is not too be used as a heating source.

•    Benzene is a chemical which is part of the gas supply to this cooking product, which is consumed in the flames during combustion. Exposure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are by-products of incomplete combustion.

•    This appliance contains or produces chemicals which can cause serious injury or death and which are known to the state of California to cause cancer, birth defects or other reproductive harm. To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed, operated, and maintained in accordance to the instructions in this document.

 

* MOVING HAZARD

To avoid risk of severe personal injury; this appliance requires two or more personnel while handling and moving. Possible use of appliance moving devices is recommended.

 

«

 

A DANGER

 

ELECTRICAL SHOCK <l4lj HAZARD

To avoid risk of electrical shock, personal injury or death; verify your appliance has been properly grounded in accordance with local codes or in absence of codes, with the National Electrical Code (NEC) ANSI/NFPA-70 -latest edition.

 

A WARNING

 

 

TIPPING HAZARD

To reduce the risk of property damage or personal injury; install anti-tipping device provided in accordance with the installation instructions in this document. Device must be engaged properly to prevent product from tipping over.

 

•    THIS RANGE CAN TIP

•    INJURIES TO PERSONS CAN RESULT

•    INSTALL ANTI-TIP DEVICE PACKED WITH RANGE

•    SEE INSTALLATION INSTRUCTIONS

 

A DANGER

 

GAS LEAK HAZARD

To avoid risk of personal injury or death; leak testing of the appliance must be conducted according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution.

 

• DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

 

36″ and 48″ W. Ranges

Note: Unit shown with standard island trim.

Note: All ranges installed with a backguard against a combustible wall require a standoff with the backguard which will add 3/4″ (1.9 cm) to the overall range depth.

Dimensions

36″ and 48″ W. Ranges

2-1/4″

(5.7 cm)

 

30″ (76.2 cm) 27-3/4 (70.5 cm)

c:

 

8″

(20.3 cm)

\j

 

35-15/16″

(91.3 cm) min. to

37-9/16″

(95.4 cm) max.

 

25-1/4″

(64.1 cm)

19-3/8″

(49.2 cm)

 

-26-15/16″

(68.4 cm)

-46-5/16″-

(117.6 cm)

Note: Unit shown with Standard island trim.

Specifications

Gas 36″ and 48″ W. Ranges
Description 36″ W. Models 48″ W. Models
Overall width 35-7/8″ (91.1 cm) 47-7/8″ (121.6 cm)
Overall height To top of side trim – 35-15/16″ (91.3 cm) min. 37-9/16″ (95.4 cm) max.

Legs adjust – 1-5/8″ (4.1 cm)

Overall depth from rear* To end of side panel – 25-1/4″ (64.1 cm)

To front of door – 26-15/16″ (68.4 cm)

To end of door handle – 30″ (76.2 cm)

*Add 3/4″ (1.9 cm) to overall depth for models installed against a combustible wall.

Additions to Base Height To top of island trim – add 1″ (.5 cm)

To top of backguard – add 10″ (25.4 cm)

To top of high shelf – add 24-1/8″ (61.3 cm)

Gas requirements Shipped Natural or LP/Propane, accepts standard residential 1/2″ (1.3 cm) ID gas service line. Unit is field convertible with Shipped Natural or LP/Propane, accepts standard residential 3/4″ (1.9 cm) ID gas service line. Unit is field convertible with
proper conversion kit proper conversion kit
Gas manifold pressure Natural 5.0″ W.C.P./ Liquid Propane L/P 10.0″ W.C.P.
Electrical

requirements

120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded

3-prong plug attached to unit

Maximum amp usage 1.5 amps 2.0 amps
Surface burner rating Natural gas/LP Front: (3) 23,000 BTU (6.7 kW) / 20,000 BTU (5.8 kW) Rear: (2) 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW) (1) 8,000 BTU (2.3 kW) / 8,000 BTU (2.3 kW) Front: (4) 23,000 BTU (6.7 kW) / 20,000 BTU (5.8 kW) Rear: (3) 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW)

(1) 8,000 BTU (2.3 kW) / 8,000 BTU (2.3 kW)

Griddle burner rating 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW)
Oven interior width 29″ (73.7 cm) Right oven – 23″ (58.4 cm)

Left oven – 12-1/2″ (31.8 cm)

Oven interior height 16-1/8″ (40.9 cm)
Oven interior depth Overall

AHAM

18-3/4(47.6 cm)

17″ (43.2 cm)

Oven volume

Overall

AHAM

5.1 cu. ft.

5.1 cu. ft.

Right – 4.0 cu. ft. / Left – 2.2 cu. ft.

Right – 3.8 cu. ft. / Left – 2.2 cu. ft.

Approximate shipping weight 525 lbs. (236.6 kg) 641 lbs. (288.5 kg)

Minimum clearances from adjacent combustible construction:

Below cooking surface (36″ [91.4 cm] and below)

•    Sides – 0″

•    Top grate support – 36″ (91.4 cm)

Above cooking surface (above 36″ [91.4 cm])

•    Sides – 12″ (30.5 cm)

•    Within 12″ (30.5 cm) side clearance, wall cabinets no deeper than 13″ (33.0 cm) must be minimum 18″ (45.7 cm) above cooking surface

•    Wall cabinets directly above product must be a minimum of 58″ (147.3 cm) above cooking surface, unless a range hood is installed above the cooking surface.

•    Rear – 3/4″ (1.9 cm) with 10″ backguard or high shelf; 0″ with island trim and non-combustible rear wall;

•    6″ (15.2 cm) with island trim and combustible rear wall

Specifications

Dual Fuel 36″ and 48″ W. Ranges
Description 36″ W. Models 48″ W. Models
Overall width 35-7/8″ (91.1 cm) 47-7/8″ (121.6 cm)
Overall height To top of side trim – 35-15/16″ (91.3 cm) min. 37-9/16″ (95.4 cm) max.

Legs adjust – 1-5/8″ (4.1 cm)

Overall depth from rear* To end of side panel – 25-1/4″ (64.1 cm)

To front of door – 26-15/16″ (68.4 cm)

To end of door handle – 30″ (76.2 cm)

*Add 3/8″ (1 cm) to overall depth for models installed against a combustible wall.

Additions to Base Height To top of island trim – add 1″ (2.5 cm)

To top of backguard – add 10″ (25.4 cm)

To top of high shelf – add 24-1/8″ (6.3 cm)

Gas requirements Shipped Natural or LP/Propane, accepts standard residential 1/2″ (1.3 cm) ID gas service line. Unit is field convertible with proper conversion kit.
Gas manifold pressure Natural 5.0″ W.C.P./ Liquid Propane L/P 10.0″ W.C.P.
Electrical

requirements

See Electrical Requirements information
Maximum amp usage 240V – 28.5 amps / 208V – 24.7 amps 240V – 43.0 amps / 208V – 37.3 amps
Surface burner rating Natural gas/LP Front: (3) 23,000 BTU (6.7 kW) / 21,500 BTU (6.3 kW) Rear: (2) 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW) (1) 8,000 BTU (2.3 kW) / 8,000 BTU (2.3 kW) Front: (4) 23,000 BTU (6.7 kW) / 21,500 BTU (6.3 kW) Rear: (3) 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW)

(1) 8,000 BTU (2.3 kW) / 8,000 BTU (2.3 kW)

Griddle burner rating 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW)
Oven interior width 30-5/16″ (77.0 cm) Right oven – 25-5/6″ (65.6 cm)

Left oven – 13-3/4″ (34.9 cm)

Oven interior height 16-1/2″ (41.9 cm)
Oven interior depth Overall

AHAM

19-1/2″ (49.5 cm)

16-13/16″ (42.7 cm)

Oven volume

Overall

AHAM

5.6 cu. ft.

4.9 cu. ft.

Right – 4.7 cu. ft. / Left – 2.6 cu. ft.

Right – 4.1 cu. ft. / Left – 2.2 cu. ft.

Approximate shipping weight 525 lbs. (236.6 kg) 692 lbs. (288.5 kg)

Minimum clearances from adjacent combustible construction:

Below cooking surface (36″ [91.4 cm] and below)

•    Sides – 0″

•    Top grate support – 36″ (91.4 cm)

Above cooking surface (above 36″ [91.4 cm])

•    Sides – 12″ (30.5 cm)

•    Within 12″ (30.5 cm) side clearance, wall cabinets no deeper than 13″ (33.0 cm) must be minimum 18″ (45.7 cm) above cooking surface

•    Wall cabinets directly above product must be a minimum of 58″ (147.3 cm) above cooking surface, unless a range hood is installed above the cooking surface.

•    Rear – 3/8″ (0.9 cm) with 10″ backguard or high shelf; 0″ with island trim and non-combustible rear wall;

•    6″ (15.2 cm) with island trim and combustible rear wall

Clearance Dimensions (Proximity to Cabinets)

 

Note: Minimum clearance for back wall is 3/4″

(1.9 cm) with backguard or high-shelf.

Note: If a range hood is installed, wall cabinets above the range have a different minimum clearance height.

 

•    This range may be installed directly adjacent to existing 36″ (91.4 cm) high base cabinets.

IMPORTANT: The side panel MUST be 3/8″ (.95 cm) above the adjacent base cabinet countertop. This can be accomplished by raising the unit using the adjustment spindles on the legs.

•    The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above

36″ (91.4 cm) high. There must be a minimum of 12″ (30.5 cm) side clearance from the range to such combustible surfaces above the 36″ (91.4 cm) counter height.

•    Within the 12″ (30.5 cm) side clearance to combustible vertical surfaces above 36″ (91.4 cm), the maximum wall cabinet depth must be 13″ (33.0 cm) and wall cabinets within this 12″ (30.5 cm) side clearance must be

18″ (45.7 cm) above the 36″ (91.4 cm) high countertop.

 

A CAUTION

 

Vi BURN HAZARD

To avoid risk of personal injury; the use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum 5″ (12.7 cm) beyond the bottom of cabinets.

 

Wall cabinets above the range must be a minimum of 58″ (147.3 cm) above the range cooking surface for the full width of the range. This minimum height requirement does not apply if a range hood is installed over the cooking surface.

 

Range

Width

“A”

Dimension

36″ 36″ (91.4 cm)
48″ 48″ (121.9 cm)

 

Clearance Dimensions (Wood/Composite Overlay)

Island Installation

 

Wall Installation

 

The bottom of a standard hood should be 30″ (76.2 cm) min. to 36″ (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66″ (167.6 cm) to 72″ (182.9 cm) above the floor. Refer to the range hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood.

 

Note: Minimum clearance for back wall is 3/4″ (1.9 cm) with backguard or high-shelf.

 

Note: This range comes standard with an Island Trim. There must be a minimum of 6″ (15.2 cm) clearance from rear of range to a combustible wall or 0″ clearance to a non-combustible wall.

Note: Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and not certified by CSA. Clearances to noncombustible materials must be approved by the authority having jurisdiction.

 

Electrical & Gas Requirements

Electrical Requirements – Gas Ranges

Check your national and local codes regarding this unit. This range requires 120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to unit. See “Electrical Connection” section for grounding instructions. Must be fused seperately from any other circuit.

Electrical Requirements – Dual Fuel Ranges

This product is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, agency approved, power supply kit with closed loop terminals rated per the National Electrical Code, ANSI/NFPA 70-latest edition (See Rating chart below). If local codes prohibit grounding through the neutral, use a 4-wire, agency approved, power supply kit with closed loop terminals rated per the National Electrical Code, ANSI/NFPA 70-latest edition (See Rating chart below).

RATING* Specified Rating of Power Supply

Cord Kit and Circuit Protection

120/240 Volts 120/208 Volts Amps

12.5    – 16.5 KW 9.2 – 12.5 KW    40 or 50

16.5    – 17.5 KW 12.5 – 13.5 KW 50

*The National Electric Code calculation for Electrical Load is less than the Total Connected Electrical Load listed on the model/serial rating plate.

 

A WARNING

 

ELECTRICAL SHOCK HAZARD

To avoid the risk of electrical shock, personal injury or death; verify electrical power is turned off at the breaker box and gas supply is turned off until the range is installed and ready to operate, installation by an authorized installer only.

 

Gas Connection

This range has a 3/4″ (1.9 cm) ID NPT Sch40) inlet connection. For optimal performance of the VGR748 Ranges, the connector from the gas supply (service) line should also be 3/4″ ID. For all other models, the gas supply (service) line may be reduced, but not to less than 1/2” (1.3 cm) ID NPT. We recommend the use of our 3/4″ GAS CONNECTOR KIT, part no. GCKVGR. Sealant on all pipe joints must be resistive to LP gas

The range is designed specifically for natural gas or liquid propane (LP) gas. Before beginning installation verify that the model is compatible with the intended gas supply.

Manual shut-off valve:

This installer-supplied valve must be installed in the gas service line before the appliance in the gas stream and in a location where it can be reached quickly in the event of an emergency. Any opening behind the range shall be sealed.

In Massachusetts: A “T” handle type manual valve must be installed in the gas supply line to the appliance.

Pressure Regulator:

• All heavy-duty, commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation, since service pressure may fluctuate with local demand. External regulators are not required on this range since a regulator is built into each unit at the factory. Under no condition bypass this built-in regulator.

 

Electrical & Gas Requirements

•    Manifold pressure should be checked with a manometer, natural gas requires 5.0″ W.C.P. and LP gas requires 10.0″ W.C.P. Incoming line pressure upstream from the regulator must be 1″ W.C.P. higher than the manifold pressure in order to check the regulator. The regulator used on this range can withstand a maximum input pressure of 1/2″ PSI (14.0″ W.C.P.). If the line pressure is in excess of that amount, a step down regulator will be required.

•    The appliance must be disconnected from the gas supply piping system during any pressure testing of that system.

 

Flexible Connections:

If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty AGA design-certified flexible connector of at least 1/2″ (1.3 cm) ID NPT (with suitable strain reliefs) in compliance with ANSI Z21.41 and Z21.69. For the VGR 48″ gas range the installer must use a flexible connector of at least 3/4″ (.9 cm) ID NPT.

In Canada: CAN 1-6, 10-88 metal connectors for gas appliances and CAN 1-6.9 M79 quick disconnect devices for use with gas fuel.

In Massachusetts: This appliance must be installed with a 36″ (3-foot) long flexible gas connector.

 

 

General Information

 

READ AND FOLLOW ALL WARNING AND CAUTION INFORMATION WHEN INSTALLING THIS APPLIANCE.

• All openings in the wall behind the appliance and in the floor under the appliance must be sealed.

 

• DO NOT obstruct the flow of combustion and ventilation air.

 

A CAUTION

 

Avoid any damage to oven vents. The vents need to be unobstructed and open to provide proper airflow for optimal oven performance.

 

A CAUTION

 

The cooling fan should be operating when the unit is in operation. If you notice the cooling fan is not operating or you observe unusual or excessive noise coming from the cooling fan, contact a Viking Authorized Service Center before continuing operation. Failure to do so can result in damage to the oven or surrounding cabinets.

 

Moving, Handling, and Unpacking

Remove and discard all packing materials, including cardboard and tape on the outside and inside of the range.

Remove the burner grates, burner heads, and bases from the cardboard top packaging.

 

DO NOT discard the metal brackets supplied with the range. These are the anti-tip devices and must be installed with the unit. Refer to “Antitip Device Installation” section.

 

Some stainless steel parts may have a plastic protective wrap which must be peeled off. The interior should be washed thoroughly with hot, soapy water to remove film residues and any dust or debris before being used, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed.

 

A WARNING

A NOTICE

 

DO NOT use the handle or oven door to lift the oven. Remove door before installation to ensure that it is not used to lift the unit. DO NOT lift or carry the door by the handle.

Removing the door must be done by your dealer, a qualified licensed plumber, or certified gas installer.

 

TO PREVENT PERSONAL INJURY

Before removing the doors, make sure the pins are properly installed in the hinges. Failure to do so can result in personal injury to hands and/or fingers.

 

Door Removal

 

Fold latches backward until locked in place

 

Slowly close until latches stop door.

 

Lift door up and out.

 

 

Installation

Leg Installation

Legs are packed in cardboard top pack. Note: Legs should be installed near to where appliance is to be used, as they are not secure for long transit.

Note: It is strongly recommended that a pallet or lift jack be used rather than tilting. Raise unit about a foot. Unscrew shipping bolts from couplings on all four corners.

 

Screw legs into couplings on all four corners.

The 48″ W. ranges have two additional legs located in the center of the unit.

 

Lower range gently to keep any undue strain from legs and internal mounting hardware.

 

Electrical Connection (3-wire) – Dual Fuel Ranges

Note: If you have a 4-wire connection, see following section for 4-wire connection instructions.

A WARNING A WARNING
V .«I Electrical shock hazard.

CWd To avoid risk or electrical

shock, personal injury or death; grounding product to the frame of the unit may or may not be permitted through your local codes. If ground to the frame is not permitted then a 4 conductor power cord must be used.

V ||| Electrical shock hazard.

Oiyj To avoid risk of electrical shock, personal injury or death; verify your appliance has been properly grounded in accordance with local codes or in absence of codes, with the National Electrical Code (NEC). ANSI/NFPA 70-latest edition.

 

See Electrical Requirements information.

Where local codes do not permit grounding through neutral, use a 4-wire power supply cord. The cord or conduit must be secured to the range with the strain relief bracket.

The electrical connection is made at the terminal block, which is located behind the access door on the back of the range.

Remove supply cord strain relief bracket and three supply cord mounting screws on terminal block.

 

Feed supply cord up through hole in bottom of range back.

 

Installation

Electrical Connection (3-wire) Dual Fuel Ranges (cont.)

Attach line #1 (red) and line #2 (black) leads to outside terminals. Attach neutral wire (white)

 

Push supply cord toward terminal block to relieve strain, reattach supply cord strain relief bracket over supply cord.

 

to center terminal on the terminal block.

 

Electrical Connection (4-wire) Dual Fuel Ranges

 

Remove supply cord strain relief bracket and three supply cord mounting screws on the terminal block.

 

Remove grounding screw. Cut-off and discard ground strap.

 

 

Feed supply cord up through hole in bottom of range back.

 

Attach ground lead (green) with ground screw that was removed.

 

Attach line #1 (red) and line #2 (black) leads to outside terminals. Attach neutral wire (white) to center terminal on terminal block.

 

Electrical Connection (4-wire) (cont.)

Push supply cord toward terminal

 

 

block to relieve strain, reattach supply cord strain relief bracket over supply cord.

 

Leveling/Adjustments/Alignment

Measure the four corners in cutout area to verify if flooring is level.

 

For uneven or sloped floors, level unit with metal shims only, as the adjustment required may exceed the thread available in the legs.

Installation

Leveling/Adjustments/Alignment (con’t)

 

Check that unit is level side to side and front to back. Side trim of the lowest corner must be 3/8″ (0.95 cm) above countertop.

 

 

 

Set the high corner of range so that the top of side trim is 3/8″ (0.95 cm) above countertop. Level range to high corner.

 

Anti-tip Device Installation (Wall Mount)

 

A WARNING

 

TIPPING HAZARD

To reduce the risk of property damage or personal injury; install anti-tipping device provided in accordance with the installation instructions in this document. Device must be engaged properly to prevent product from tipping over.

Range

Width

“X”

Dimension

36″ 24-5/8″ (62.5 cm)
48″ 22-3/4 (57.8 cm)

 

Locate anti-tip bracket on rear wall with the top left corner at measurement (A) plus 1/2″ (1.3 cm) from the floor and “X” from where the right side of range (facing range) is to be located.

 

Measure from floor to bottom of the anit-tip opening located on the back of range. This will be measurement (A).

Mark and drill holes where bracket will be located.

 

Anti-tip Device Installation (Floor Mount)

 

Locate anti-tip bracket hook on the floor 8-1/2″ (21.6 cm) from side cabinet and 1-1/2″ (3.8 cm) from rear wall. Mark and drill 1/8″ (.32 cm) holes where bracket will be located.

Mount anti-tip bracket hook to floor using screws provided.

 

Remove two screws from back of range.

Attach bracket to back of range using two screws.

 

 

Connecting Gas & Electric

A DANGER

GAS LEAK HAZARD

To avoid risk of personal injury or death; leak testing of the appliance must be conducted according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution.

• DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

 

Connect gas and electrical. Before placing appliance in operation, always check for gas leaks. This must be performed by your dealer, a qualified licensed plumber, or gas service company.

 

Installation

Standoff Spacer Removal

A DANGER

urn/ FIRE hazard

Backguards come standard with standoff spacers which provide a barrier between back of range and rear wall. These must be in place for adequate ventilation. Standoff spacers can only be removed if range is installed against a Non-Combustible wall.

Final Installation

 

 

 

Slide range into place. Be sure wall anit-tip bracket slides into the anit-tip opening and floor anti-tip hook and bracket are engaged.

 

Burner heads and bases are packed in cardboard top pack with the grates. Place burner bases on top of the burner flanges and burner heads on top of the burner base. Place burner grate on top of grate support. (See “Proper alignment of Burner Head”.)

 

 

and front to back. The side trim must be 3/8″ (0.95 cm) above countertop. If unit is not level repeat Steps 5-7 of “Leveling/Adjustments/Alignment” section.

 

Proper alignment of Burner Head

locator graphic

 

When placing the burner head on the burner base, carefully align the locator key in the outer edge below the burner ports with the small notch in the top front edge of the burner base. This will align the burner port with the ignitor. When properly installed, the locator graphic will be aligned with the ignitor and opposite the locator pin.

Door Replacement

 

locator pin    burner base notch

 

Close door.

 

Open door completely. Fold latches forward until locked in place.

 

  • Final Preparation